CFP last date
20 May 2024
Reseach Article

Image Enhancement based Improved Multi-scale Hessian Matrix for Coronary Angiography

by Kaifeng Chen, Qingbo Yin, Xiao Jia, Mingyu Lu
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 126 - Number 10
Year of Publication: 2015
Authors: Kaifeng Chen, Qingbo Yin, Xiao Jia, Mingyu Lu
10.5120/ijca2015906196

Kaifeng Chen, Qingbo Yin, Xiao Jia, Mingyu Lu . Image Enhancement based Improved Multi-scale Hessian Matrix for Coronary Angiography. International Journal of Computer Applications. 126, 10 ( September 2015), 1-4. DOI=10.5120/ijca2015906196

@article{ 10.5120/ijca2015906196,
author = { Kaifeng Chen, Qingbo Yin, Xiao Jia, Mingyu Lu },
title = { Image Enhancement based Improved Multi-scale Hessian Matrix for Coronary Angiography },
journal = { International Journal of Computer Applications },
issue_date = { September 2015 },
volume = { 126 },
number = { 10 },
month = { September },
year = { 2015 },
issn = { 0975-8887 },
pages = { 1-4 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume126/number10/22585-2015906196/ },
doi = { 10.5120/ijca2015906196 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T23:17:03.323745+05:30
%A Kaifeng Chen
%A Qingbo Yin
%A Xiao Jia
%A Mingyu Lu
%T Image Enhancement based Improved Multi-scale Hessian Matrix for Coronary Angiography
%J International Journal of Computer Applications
%@ 0975-8887
%V 126
%N 10
%P 1-4
%D 2015
%I Foundation of Computer Science (FCS), NY, USA
Abstract

The coronary angiography image is easy to be affected by many factors, such as vascular thickness varied huge, complex background noise, uneven illumination intensity and so on. The coronary angiography image is more difficult to deal with compared with other similar medical images. By using Hessian matrix multi-scale vascular detection method, the vicinity of blood vessels will yield a lot of background noise, and the small tiny blood vessels become blurred or even lost, which seriously affect the experiment results. In this paper, an improved multi-scale Hessian matrix is presented, combined with morphological top-hat operation for the detection of coronary angiography. The experimental results demonstrate the effectiveness of the proposed method.

References
  1. Poli, Riccardo, and Guido Valli. "An algorithm for real-time vessel enhancement and detection." Computer methods and programs in Biomedicine 52.1 (1997): 1-22.
  2. Sun, K. Q., and N. Sang. "Morphological enhancement of vascular angiogram with multiscale detected by Gabor filters." Electronics Letters 44.2 (2008): 86-87.
  3. Zeng, Ming, Jianxun Li, and Zhang Peng. "The design of top-hat morphological filter and application to infrared target detection." Infrared Physics & Technology 48.1 (2006): 67-76.
  4. Bai, Xiangzhi, and Fugen Zhou. "Analysis of new top-hat transformation and the application for infrared dim small target detection." Pattern Recognition 43.6 (2010): 2145-2156.
  5. Shi, Fei, and Jian Yang. "Multiscale vesselness based bilateral filter for blood vessel enhancement." Electronics letters 45.23 (2009): 1152-1154.
  6. Hooshyar, Sina, and Rasoul Khayati. "Retina vessel detection using fuzzy ant colony algorithm." Computer and Robot Vision (CRV), 2010 Canadian Conference on. IEEE, 2010.
  7. Manniesing, Rashindra, Max A. Viergever, and Wiro J. Niessen. "Vessel enhancing diffusion: A scale space representation of vessel structures." Medical image analysis 10.6 (2006): 815-825.
  8. Frangi, Alejandro F., et al. "Multiscale vessel enhancement filtering." Medical Image Computing and Computer-Assisted Interventation—MICCAI’98. Springer Berlin Heidelberg, 1998. 130-137.
  9. Lindeberg, Tony. "Edge detection and ridge detection with automatic scale selection." International Journal of Computer Vision 30.2 (1998): 117-156.
  10. Chakraborti, Tapabrata, et al. "A self-adaptive matched filter for retinal blood vessel detection." Machine Vision and Applications 26.1 (2014): 55-68.
  11. Hiriart-Urruty, Jean-Baptiste, Jean-Jacques Strodiot, and V. Hien Nguyen. "Generalized Hessian matrix and second-order optimality conditions for problems withC 1, 1 data." Applied mathematics and optimization 11.1 (1984): 43-56.
  12. Bofill, Josep Maria. "Updated Hessian matrix and the restricted step method for locating transition structures." Journal of Computational Chemistry 15.1 (1994): 1-11.
  13. Liping Chen. "Blood vessel image enhancement and level set segmentation algorithm based on Hessian matrix." [D]. Diss. Hunan University, 2012.
  14. Qin Zhang. "The extraction method research for blood vessel trees of coronary angiography images." MS thesis. Dalian Maritime University, 2012.
Index Terms

Computer Science
Information Sciences

Keywords

Image enhancement Hessian Matrix Morphological top-hat Vessel detection Coronary angiography