Article:Fuzzy Logic Control based Three Phase Shunt Active Filter for Voltage Regulation and Harmonic Reduction

by G. Jayakrishna, K.S.R.Anjaneyulu
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 10 - Number 5
Year of Publication: 2010
Authors: G. Jayakrishna, K.S.R.Anjaneyulu
10.5120/1479-1996

G. Jayakrishna, K.S.R.Anjaneyulu . Article:Fuzzy Logic Control based Three Phase Shunt Active Filter for Voltage Regulation and Harmonic Reduction. International Journal of Computer Applications. 10, 5 ( November 2010), 13-19. DOI=10.5120/1479-1996

@article{ 10.5120/1479-1996,
author = { G. Jayakrishna, K.S.R.Anjaneyulu },
title = { Article:Fuzzy Logic Control based Three Phase Shunt Active Filter for Voltage Regulation and Harmonic Reduction },
journal = { International Journal of Computer Applications },
issue_date = { November 2010 },
volume = { 10 },
number = { 5 },
month = { November },
year = { 2010 },
issn = { 0975-8887 },
pages = { 13-19 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume10/number5/1479-1996/ },
doi = { 10.5120/1479-1996 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T19:58:56.365645+05:30
%A G. Jayakrishna
%A K.S.R.Anjaneyulu
%T Article:Fuzzy Logic Control based Three Phase Shunt Active Filter for Voltage Regulation and Harmonic Reduction
%J International Journal of Computer Applications
%@ 0975-8887
%V 10
%N 5
%P 13-19
%D 2010
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This paper studies a Fuzzy Logic Control Based (FLCB) Shunt Active Filter (SAF) capable of reducing the total harmonics distortion (THD) in Power System (PS). SAF is one of the key controllers in Flexible Alternating Current Transmission System (FACTS) to control the transmission line voltage and can be used in PS to enhance the power transmission capacity and extend the transient stability. In order to improve the power factor, compensate the reactive power and suppress the total harmonic distortion (THD) drawn from a Non-Linear Diode Rectifier Load (NLDRL) of SAF, we propose a Hysteresis Current Pulse Width Modulation (HCPWM) technique which is used as control for the switches of the Voltage Source Inverter (VSI) or SAF. The synchronous reference D-Q frame theory is used to generate the reference compensating currents for SAF. A fuzzy logic based control is developed to regulate the voltage of the DC capacitor. The system with control scheme is implemented in Matlab/Simulink. The simulation results show the effectiveness of the proposed method for harmonic damping and voltage regulation.

References
  1. Roger C.Dugan, Mark F. McGranaghan, Surya Santoso and H.Wayne Beaty, Electrical Power System Quality, McGraw –Hill.
  2. Bhim Singh, Kamal Al Haddad and Ambrish Chandra, A Review of Active Filters for Power Quality Improvement, IEEE Trans on Industrial Electronics, Vol.46, No.5, October 1999, pp. 960-970.
  3. Zainal Salam, Tan Perng Cheng and Awang Jusoh, Harmonics Mitigation using Active Power Filter: A Technological Review Elekrika, Vol.8, No.2, 2006, 17-26.
  4. Y.Sato, T.Kawase, M.Akiyama, and T.Kataoka, A control strategy for general – purpose active filters based on voltage detection, IEEE Trans. Ind. Appl., vol. 36, no.5, pp.1405–1412, Sep / Oct.2000.
  5. M. Kazmierkowsi, L.Malesani,Current Control Techniques for Three Phase Voltage Source PWM converters: A survey, IEEE Trans on Industrial Electronics, vol.45, no.5, pp.691- 703, October 1998.
  6. S. Buso, L. Malesani, P. Mattavelli, Comparison of current control Techniques for Active power Filter Applications, IEEE Transactions on Industrial Electronics, Vol.45, no.5, pp.722-729, Oct 1998.
  7. E.E.EL-Khoy, A. EL-Sabbe, A.El-Hefnawy, and Hamdy M.Mharous, Three phase active power filter based on current controlled voltage source inverter, Electrical Power and Energy Systems, 28 (2006), 537-547.
  8. S.K.Jain, P.Agrawal and H.O.Gupta, Fuzzy Logic controlled shunt active power filter for power quality improvement, IEE proceedings in Electrical Power Applications, Vol 149, No.5, September 2002.
  9. V. Agelidis, M. Calais, Application specific harmonic performance evaluation of multicarrier PWM techniques, IEEE-PESC’98 Conference Record, pp. 172-178, 1998.
  10. G. Carrara, S. Gardelta, M. Marchesoni, A new multilevel PWM method: theoretical analysis, IEEE Trans. On power electronics Vol. 7. No. 3, July, pp.497-505, 1992.
Index Terms

Computer Science
Information Sciences

Keywords

Power systems Shunt active filter Fuzzy logic based control Voltage regulation Hysteresis current pulse width modulation D-Q reference frame theory