CFP last date
21 October 2024
Reseach Article

A Review of Harmonics Detection and Measurement in Power System

by Snehal R. Durdhavale, Dnyaneshwar D. Ahire
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 143 - Number 10
Year of Publication: 2016
Authors: Snehal R. Durdhavale, Dnyaneshwar D. Ahire
10.5120/ijca2016910394

Snehal R. Durdhavale, Dnyaneshwar D. Ahire . A Review of Harmonics Detection and Measurement in Power System. International Journal of Computer Applications. 143, 10 ( Jun 2016), 42-45. DOI=10.5120/ijca2016910394

@article{ 10.5120/ijca2016910394,
author = { Snehal R. Durdhavale, Dnyaneshwar D. Ahire },
title = { A Review of Harmonics Detection and Measurement in Power System },
journal = { International Journal of Computer Applications },
issue_date = { Jun 2016 },
volume = { 143 },
number = { 10 },
month = { Jun },
year = { 2016 },
issn = { 0975-8887 },
pages = { 42-45 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume143/number10/25117-2016910394/ },
doi = { 10.5120/ijca2016910394 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T23:46:04.555173+05:30
%A Snehal R. Durdhavale
%A Dnyaneshwar D. Ahire
%T A Review of Harmonics Detection and Measurement in Power System
%J International Journal of Computer Applications
%@ 0975-8887
%V 143
%N 10
%P 42-45
%D 2016
%I Foundation of Computer Science (FCS), NY, USA
Abstract

A load is said to be “linear” when it draws a current from the supply which is proportional to the applied voltage (linear). And in the case of “non-linear” load, impedance changes with applied voltage. The current drawn from such non-linear load is also non-linear i.e. non-sinusoidal even when it is connected to a sinusoidal voltage source. Harmonic currents contents which are present in non-sinusoidal currents intermingle with the impedance of the power distribution system to create voltage distortion which affects the distribution system and the loads connected to it. The serious power-line pollution is a result of increasing use of power electronic systems and time-variant nonlinear loads in industry. Hence, power supply quality is degraded. It results in the reduction of system efficiency, apparatus overheating, and increase power. As the utilization of the number of harmonics-producing loads has increased over the years, it has become highly mandatory their influence and analysis when making any additions or changes to an installation. In this paper various harmonics detection and measurement techniques have been outlined.

References
  1. Harmonics Detection and Filtering, Low Voltage Expert Guides by Schneider Electric.
  2. Harmonics in Your Electric System, A White Paper of Eaton Corporation.
  3. Douglas Andrews, Martin T. Bishop, John F. Witte,(May-June 1996), Harmonic Measurements, Analysis, and Power Factor Correction in a Modern Steel Manufacturing Facility, IEEE Transactions on Industry Applications, Vol. 32, No. 3.
  4. Lucian As iminoae,, Sergej Kalaschnikow and Steffan Hansen, Two harmonic detection methods used in industrial shunt active filters
  5. Masoud Karimi-Ghartemani, and M. Reza Iravani,( January 2005), Measurement of Harmonics/Inter-harmonics of Time-Varying Frequencies, IEEE Transactions On Power Delivery, Vol. 20, No.3.
  6. David M. McNamara, Alireza K. Ziarani, Thomas H. Ortmeyer(January 2007), A New Technique of Measurement of Nonstationary Harmonics, IEEE Transactions On Power Delivery, Vol. 22, No.1
  7. Weicheng XIE, Xia YANG, (2010), A Power Harmonic Measurement System Based on Wavelet Packet Transform and ARM9, IEEE.
  8. Gary W. Chang, Senior Member, IEEE and Cheng-I Chen, (2010), Measurement Techniques for Stationary and Time-Varying Harmonics, IEEE
  9. Shouxi Zhu, Wenlai Ma, (2012), Design of Power Harmonic Detection Instrument Based on DSP and ARM, CISME Vol.2 No.2
  10. Hsiung Cheng Lin, (February 2012),Power Harmonics and Interharmonics Measurement Using Recursive Group-Harmonic Power Minimizing Algorithm, IEEE Transactions On Industrial Electronics, Vol. 59, No.2
  11. Jaipreet Kaur Bhatti, Deepak Asati, (June 2012), Harmonic Detection using Microcontroller, International Journal of Computer Technology and Electronics Engineering (IJCTEE) Volume 2, Issue 3.
  12. Yi Fei Wang,Yun Wei Li,(2013), An Overview of Grid Fundamental and Harmonic Components Detection Techniques, IEEE
  13. Zhaobi CHU, Ming DING, Shaowu DU, Xueping DONG, (2013), Normalized estimation of fundamental frequency And measurement of harmonics/interharmonics.
  14. Alexander Kamenka, (2014) Six Tough Topics about Harmonics Distortion and Power Quality Indices in Electric Power System, A White Paper of Schaffner Group.
  15. Jeena Joy, Amalraj P.M., Aswin Raghunath, Nidheesh M.N Vinu Joseph,(August 2014), Harmonic Analysis of 230 V AC Power Supply Using LPC2138 Microcontroller, Transactions on Engineering and Sciences ,Vol.2, Issue 8.
  16. Manish Kumar Soni, Nisheet Soni, (February 2014), Review of Causes and Effect of Harmonics on Power System , International Journal of Science, Engineering and Technology Research (IJSETR), Volume 3, Issue 2.
  17. J. R. Demers, B. Kasper1, D.R. Daughton, (2015), Simultaneous measurement of the 1st and 2nd harmonics of a phase modulated coherent frequency-domain THz spectrometer
  18. Feng Guihong, Zhang Jing, Zhao Yisong , Ying Yong, Zhang Bingyil, Harmonic Power Detection and Measurement Device Based on Harmonic Power Flow Analysis.
Index Terms

Computer Science
Information Sciences

Keywords

Non-linear loads harmonic currents power distribution system voltage distortion power signal quality harmonic distortion.