Reseach Article

Shunt Hybrid Power Filter for Harmonic Reduction to Improve Power Quality using PI and Hysteresis Controller

by Saduf Shabeer, Ashish Grover, Abdul Hamid Bhat
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 147 - Number 4
Year of Publication: 2016
Authors: Saduf Shabeer, Ashish Grover, Abdul Hamid Bhat
10.5120/ijca2016910968

Saduf Shabeer, Ashish Grover, Abdul Hamid Bhat . Shunt Hybrid Power Filter for Harmonic Reduction to Improve Power Quality using PI and Hysteresis Controller. International Journal of Computer Applications. 147, 4 ( Aug 2016), 7-12. DOI=10.5120/ijca2016910968

@article{ 10.5120/ijca2016910968,
author = { Saduf Shabeer, Ashish Grover, Abdul Hamid Bhat },
title = { Shunt Hybrid Power Filter for Harmonic Reduction to Improve Power Quality using PI and Hysteresis Controller },
journal = { International Journal of Computer Applications },
issue_date = { Aug 2016 },
volume = { 147 },
number = { 4 },
month = { Aug },
year = { 2016 },
issn = { 0975-8887 },
pages = { 7-12 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume147/number4/25639-2016910968/ },
doi = { 10.5120/ijca2016910968 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T23:50:59.101312+05:30
%A Saduf Shabeer
%A Ashish Grover
%A Abdul Hamid Bhat
%T Shunt Hybrid Power Filter for Harmonic Reduction to Improve Power Quality using PI and Hysteresis Controller
%J International Journal of Computer Applications
%@ 0975-8887
%V 147
%N 4
%P 7-12
%D 2016
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Shunt hybrid power filter are extensively used for current harmonic elimination and to compensate reactive power for linear/nonlinear loads and to improve input power factor. Hybrid power filter is thus used as practical solution to solve the electric power quality (EOQ) issues. Hybrid filter consists of a shunt active power filter (SAPF) and passive filters .Shunt active power filter operates at a very low switching frequency, thus giving higher conversion efficiency. The combined operation of shunt active power filter and passive filter ensures total harmonic distortion (THD) of source current should be within the permissible limits set by various regulatory agencies ie THD=<5% and supply power factor is near unity. The effectiveness of the hybrid filter has been verified by the extensive simulation results carried out in MATLAB/Simulink and Sim Power System software.

References
  1. Farooq, A. and Bhat, A.H., (2015),” Performance Evaluation of a Three phase Shunt Active Power Filter For power Quality Improvement.”
  2. Report by Deepak C.Bhonsle. “Design and implementation of single phase shunt active power filter for harmonic mitigation in distribution system” The M.S.University of Baroda.
  3. H. Akagi, “Active harmonic filters,” Proc. IEEE, vol. 93, no.12,pp.2128–2141,Dec.2005
  4. Jacobs J,Detjen” D,-A new hybrid filter versus a shunt power filter”, in European conference on pwer electronics &amp;applications,Graz,Ausreia 2001.
  5. Prof.dr.Dobariya,Prof.P.Upadhyay,(2015),”Simulation and comparison between hybrid active power filter and shunt active power filter.”
  6. Engin Ozdemir, Mehmet Uca,r Metin Kesler, Murat Kale.” The Design and Implementation of a Shunt Active Power Filter based on Source Current Measurement ” 1 -4244-0743-5/07/$20.00 ©2007 IEEE pp. 608 to 613
  7. Moleykutty George and Kartik Prasad Basu, “Modeling and Control of Three Phase Shunt Active Power Filter,” in American Journal of Applied Sciences 5 (8): 1064-1070, 2008.
  8. S. J. Huang, J. C. Wu and D. D. Divan, ‘‘A control algorithm for three phase three-wired active power filters under nonideal mains voltages,’’ IEEE Transactions on Power Electronics, vol. 14, pp. 753---760, July 1999.
  9. M.Sarra,K.Djazia,A.Chaoui,F.Krim,“Three-phase Active Power filter with Proportional Integral control,” Journal of Electrical Systems Issue no.1,pp 79-84,Nov.2009.
  10. Asiminoaei, L. F. S. Blaabjerg, Hansen. ―Evaluation of harmonic detection methods for active power filter applications‖, APEC2 5, Vol.1 pp 635-641
Index Terms

Computer Science
Information Sciences

Keywords

THD (total harmonic distortion) PI(proportional integral) controller EPQ(electrical power quality) APLC(active power load conditioner) SAPF (shunt active power filter) APF(active power filter)