CFP last date
20 May 2024
Reseach Article

A Method to Simulate Treatment of Thyroid Problems in the Human Body

by Rishma Chawla, Yash Pal
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 98 - Number 12
Year of Publication: 2014
Authors: Rishma Chawla, Yash Pal
10.5120/17237-7570

Rishma Chawla, Yash Pal . A Method to Simulate Treatment of Thyroid Problems in the Human Body. International Journal of Computer Applications. 98, 12 ( July 2014), 37-40. DOI=10.5120/17237-7570

@article{ 10.5120/17237-7570,
author = { Rishma Chawla, Yash Pal },
title = { A Method to Simulate Treatment of Thyroid Problems in the Human Body },
journal = { International Journal of Computer Applications },
issue_date = { July 2014 },
volume = { 98 },
number = { 12 },
month = { July },
year = { 2014 },
issn = { 0975-8887 },
pages = { 37-40 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume98/number12/17237-7570/ },
doi = { 10.5120/17237-7570 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:26:02.883385+05:30
%A Rishma Chawla
%A Yash Pal
%T A Method to Simulate Treatment of Thyroid Problems in the Human Body
%J International Journal of Computer Applications
%@ 0975-8887
%V 98
%N 12
%P 37-40
%D 2014
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This is an effort to simulate the concept of treatment of different types of Thyroidism after determining the TSH, T3 and T4 levels in the human body. The target is to determine the effective dose of Thyroxine to be provided to the patient so that normal level of the same can be maintained in the human body. It interacts with every organ system and plays a crucial role in metabolism [1], but there is no software technique to bypass the doctors for the treatment of Thyroid malfunctioning. The Analog devices like operational amplifiers have features identical to the arithmetic operations. Primarily, the voltages in the high-gain dc amplifiers can be reduced to an average to these three variables and the operational amplifiers can do the arithmetic operations on the voltages, the accuracy of measuring voltage may be circumscribed to limited point. A Digital circuit has been implemented to determine the dosage required by the patients using the best market products. The simulation has been done using CircuitMaker ( Student version).

References
  1. Becker KL, Smallridge RC, Wartofsky L. Part III: The thyroid gland. Chapter 33: Thyroid function tests. In: Principles and Practice of Endocrinology and Metabolism. 3rd ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2002.
  2. Braverman LE, Utiger RD, eds. The Thyroid: Fundamental and Clinical Text. 9th ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2005.
  3. Jose Ramon Alvero, Cruz, Mauro Ronconi, Margarita, Carrillo De Albornoz, Gil, Jeronimo C. , Garcia Romero, Daniel Rosado Velazquez, A. Mario De Diego Acosta, Thyroid hormones response in simulated laboratory sprint duathlon, Journal Of Human Sport & Exercise, ISSN 1988-5202, 2011.
  4. Eisenberg M1, Samuels M, DiStefano JJ 3rd. , Extensions, validation, and clinical applications of a feedback control system simulator of the hypothalamo-pituitary-thyroid axis, doi: 10. 1089/ thy. 2007. 0388, 2008.
  5. Maia AL, Kim BW, Huang SA, et al. Type 2 iodothyronine deiodinase is the major source of plasma T3 in euthyroid humans. J Clin Invest. 2005:115;2524-2533.
  6. AACE press release of January 2003.
  7. Yash Pal, Vikas Verma, Rishma Chawla, " Determination of Thyroid Disorders in the Human Body using TSH, T3 and T4 levels", International Journal of Computer Applications(0975-8887), Volume 94-No. 8, May, 2014.
  8. Nicoloff JT, Spencer CA. The use and misuse of the sensitive thyrotropin assays. J Clin En-docrinol Metab. 1990;71:553-558.
  9. I. S. Isa, Z. Saad, S. Omar, M. K. Osman, K. A. Ahmad, H. A. Mat Sakim, "Suitable MLP Network Activation Functions for Breast Cancer and Thyroid Disease Detection," cimsim, pp. 39-44, 2010 Second International Conference on Computational Intelligence, Modelling and Simulation, 2010.
  10. Walter F. , PhD. Boron , Chapter 48, "Synthesis of Thyroid Hormones Medical Physiology: A Cellular And Molecular Approach," Elsevier/Saunders. p. 1300. ISBN 1-4160-2328-3 2003.
  11. Professor G. Wainer, "Modelling and Simulation of the Human Liver," Biomedical Applications, Department of Systems and Computer Engineering, Faculty of Engineering, Carleton University.
  12. Georg Hennemann, Roelof Docter, Edith C. H. Friesema, Marion de Jong, Eric P. Krenning and Theo J. Visser, "Plasma Membrane Transport of Thyroid Hormones and Its Role in Thyroid Hormone Metabolism and Bioavailability, Endocrine Reviews". August 2001, 22(4):451–476.
  13. John C. Morris, "How do You Approach the Problem of TSH Elevation in a Patient on High-dose Thyroid Hormone Replacement?" Disclosures, Int J Qual Health Care. 2009;70(5):671-673.
  14. John B. Tourtelot, Assistant Clinical Professor of Medicine, University of South Florida, Tampa, FL, RPh, MD, "Precise Dosing of Levothyroxine" Disclosures, June 1, 2007, Supported by Abbott Laboratories.
  15. Murray, Francis J. , Mathematical Machines, vol. 2 Analog Devices, New York: Columbia Press, 1961.
  16. Walt Kester, Editor, High Speed Design Techniques, Analog Devices, 1996, ISBN0-916550-17-6.
  17. Robert Paz, Analog Computer Programming
  18. Pierre-Frederic Villard, Piers Boshier, Fernando Bello and Derek Gould, "Virtual Reality Simulation of Liver Biopsy with a Respiratory Component. " Imperial College, London, LORIA, Nancy University, Royal Liverpool Hospital, Liverpool.
  19. Yash Pal, "An Analog Method to study Average Memory Access time in a compuer system," Proceedings of the World Congress on Engineering, 2013 Vol II, London, UK, 2013.
  20. Alpco Diagnostics, "T4 (Thyroxine) (Free) LIA For the quantitative determination of of free T4 in serum," Version: 5. 0 May 18, 2011 – ALPCO, 2012.
Index Terms

Computer Science
Information Sciences

Keywords

TSH (Thyroid Stimulating Hormones) T4( Thyroxine) Neomercazole Eltroxin and OPAMPs