CFP last date
20 May 2024
Reseach Article

Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design

by Mai S. Mabrouk, Olfat A. Kandil
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 41 - Number 12
Year of Publication: 2012
Authors: Mai S. Mabrouk, Olfat A. Kandil
10.5120/5592-7350

Mai S. Mabrouk, Olfat A. Kandil . Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design. International Journal of Computer Applications. 41, 12 ( March 2012), 10-16. DOI=10.5120/5592-7350

@article{ 10.5120/5592-7350,
author = { Mai S. Mabrouk, Olfat A. Kandil },
title = { Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design },
journal = { International Journal of Computer Applications },
issue_date = { March 2012 },
volume = { 41 },
number = { 12 },
month = { March },
year = { 2012 },
issn = { 0975-8887 },
pages = { 10-16 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume41/number12/5592-7350/ },
doi = { 10.5120/5592-7350 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T20:29:28.058935+05:30
%A Mai S. Mabrouk
%A Olfat A. Kandil
%T Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design
%J International Journal of Computer Applications
%@ 0975-8887
%V 41
%N 12
%P 10-16
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

The progress in the field of electronics and technology as well as the processing of signals coupled with advance in the use of computer technology has given the opportunity to record and analyze the bio-electric signals from the human body in real time that requires dealing with many challenges according to the nature of the signal and its frequency. This could be up to 1 kHz, in addition to the need to transfer data from more than one channel at the same time. Moreover, another challenge is a high sensitivity and low noise measurements of the acquired bio-electric signals which may be tens of micro volts in amplitude. For these reasons, a low power wireless Electromyography (EMG) data transfer system is designed in order to meet these challenging demands. In this work, we are able to develop an EMG analogue signal processing hardware, along with computer based supporting software. In the development of the EMG analogue signal processing hardware, many important issues have been addressed. Some of these issues include noise and artifact problems, as well as the bias DC current. The computer based software enables the user to analyze the collected EMG data and plot them on graphs for visual decision making. The work accomplished in this study enables users to use the surface EMG device for recording EMG signals for various purposes in movement analysis in medical diagnosis, rehabilitation sports medicine and ergonomics. Results revealed that the proposed system transmit and receive the signal without any losing in the information of signals.

References
  1. A. Cohen, "Biomedical Signals: Origin and Dynamic Characteristics; Frequency Domain Analysis," in the Biomedical Engineering Handbook, J. Bronzino Ed. Boca Raton, CRC Press, 1995.
  2. Antti T. Vehkaoja, Jarmo A. Verho, Merja M. Puurtinen, Niina M. Nöjd, Jukka O. Lekkala, and Jari A. Hyttinen, Member, IEEE, "Wireless Head Cap for EOG and Facial EMG Measurements", Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference Shanghai, China, September 1-4, 2005
  3. Webster, John G. (1998). Medical Instrumentation: Application and Design.
  4. Crosbie, J. H. , Lennon, S. , Basford, J. R. , & McDonough, S. M, "Virtual reality in stroke rehabilitation: Still more virtual than real". Disability and Rehabilitation, 29(14), 1139 – 1146, 2007.
  5. Y. T. Yu, M. F. Lau, "A comparison of MC/DC, MUMCUT and several other coverage criteria for logical decisions", Journal of Systems and Software, 2005.
  6. Abbink, V. D. B. , Glas, V. D. , "Detection of onset and termination of muscle activity in surface electromyograms", Journal of Oral Rehabilitation, 25(5), 365-369. 1998.
  7. Hassoun, M. H. , Wang, C. , Spitzer, A. R. , "NNERVE: Neural network extraction of repetitive vectors for electromyography II, performance analysis. IEEE Transactions on Biomedical Engineering, 41(11), 1053-1061, 1994.
  8. Vehkaoja, A. , Lekkala, J. , "Wearable Wireless Biopotential Measurement Device," in Proceedings of the 26th Annual Engineering in Medicine and Biology Conference, San Francisco, pp. 2177 – 2179, 2004.
  9. [Hughes, E. , Bell, A. , "A Wireless Surface Electromyography System, IEEE Southeast Conference Proceedings, 253, 2007.
  10. Eisenhower, W. , McMichael, S. , "Analog control with surface electromyography, Electrical and Computer Engineering. University of Maryland, College Park, 2005.
  11. B. D. Farnsworth, R. J. Triolo and D. J. Young, "Wireless Implantable EMG Sensing Microsystem", IEEE Sensors Conference, pp. 1245-1248, 2008.
  12. Noraxon, I. (2010). Zero-Wire - True Wireless EMG Retrieved 4 April 2010.
  13. M. Suster, J. Guo, N. Chaimanonart, W. H. Ko, and D. J. Young, "A Wireless Strain Sensing Microsystem with External RF Powering and Two-Channel Data Telemetry Capability," ISSCC, pp. 380-381, 2007.
  14. Op Amps for Everyone, Ron Mancini (Ed. ), Chapter 12, Texas Instruments Literature Number SLOD006.
  15. N. Chaimanonart, M. Suster, and D. J. Young, "Two- Channel Data Telemetry with Remote RF Powering for High-Performance Wireless MEMS Strain Sensing Applications", IEEE Sensors Conference, pp. 285-288, 2005.
  16. Pelland, L. , McKinley, P. , "A pattern recognition technique to characterize the differential modulation of co-activating muscles at the performer/environment interface", Journal of Electromyography and Kinesiology, 14, 539-554, 2004.
  17. Raez, M. B. I. , Hussain, S. , Mohd-Yasin, F, "Techniques of EMG signal analysis: Detection, processing, classification and applications", Biological Procedures Online, 8, 11-35, 2006.
  18. De Michele, G. , Sello, S. , Carboncini, M. C. , Rossi, B. , & Strambi, S. , "Cross-correlation time-frequency analysis for multiple EMG signals in Parkinson's diease: A wavelet approach", Medical Engineering and Physics, 25(5), 361-369, 2003.
  19. Jaskolska A , Kisiel-Sajewicz K, Brzenczek-Owczarzak W, Yue G H. c, Jaskolski A, " EMG and MMG of agonist and antagonist muscles as a function of age and joint angle", Journal of Electromyography and Kinesiology 16, 89–102, 2006.
  20. Evetovich T K, Naumann J, Conley D S, and Todd J B, " Effect of Static Stretching of the Biceps Brachii on Torque, Electromyography, and Mechanomyography During Concentric Isokinetic Muscle Actions", Journal of Strength and Conditioning Research, 17(3), 484–488, 2003.
Index Terms

Computer Science
Information Sciences

Keywords

Electromyography Wireless Biceps Brachii Muscle Surface Electrodes Data Acquisition Instrument