CFP last date
20 May 2024
Reseach Article

Comparative Study on Carrier Overlapping PWM Strategies for Three Phase Five Level Cascaded Inverter

by C. R. Balamurugan, S. P. Natarajan, R. Bensraj
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 48 - Number 6
Year of Publication: 2012
Authors: C. R. Balamurugan, S. P. Natarajan, R. Bensraj
10.5120/7351-0048

C. R. Balamurugan, S. P. Natarajan, R. Bensraj . Comparative Study on Carrier Overlapping PWM Strategies for Three Phase Five Level Cascaded Inverter. International Journal of Computer Applications. 48, 6 ( June 2012), 20-28. DOI=10.5120/7351-0048

@article{ 10.5120/7351-0048,
author = { C. R. Balamurugan, S. P. Natarajan, R. Bensraj },
title = { Comparative Study on Carrier Overlapping PWM Strategies for Three Phase Five Level Cascaded Inverter },
journal = { International Journal of Computer Applications },
issue_date = { June 2012 },
volume = { 48 },
number = { 6 },
month = { June },
year = { 2012 },
issn = { 0975-8887 },
pages = { 20-28 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume48/number6/7351-0048/ },
doi = { 10.5120/7351-0048 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T20:43:22.904818+05:30
%A C. R. Balamurugan
%A S. P. Natarajan
%A R. Bensraj
%T Comparative Study on Carrier Overlapping PWM Strategies for Three Phase Five Level Cascaded Inverter
%J International Journal of Computer Applications
%@ 0975-8887
%V 48
%N 6
%P 20-28
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This paper presents the comparison of Carrier Overlapping Pulse Width Modulation (COPWM) techniques for the Cascaded Multi Level Inverter (CMLI). A CMLI is controlled in this paper with Sinusoidal PWM (SPWM) reference, Third Harmonic Injection PWM (THI PWM) reference, Sixty degree PWM reference and Stepped wave reference with Carrier Overlapping (CO) techniques. The variation of Total Harmonic Distortion (THD) in the inverter output voltage is observed when the chosen inverter is controlled by SPWM for various modulation indices. Simulation is performed using MATLAB-SIMULINK. It is observed that COPWM-C provides output with relatively low distortion for all strategies. It is also seen that COPWM-A is found to perform better for all strategies since it provides relatively higher fundamental RMS output voltage and in particular highest output is obtained for 60 degree PWM reference.

References
  1. Donald Grahame Holmes, P. Brendam and Mcgrath, "Opportunities for Harmonic Cancellation with Carrier-Based PWM for Two-Level and Multilevel Cascaded Inverters", IEEE Trans. on Industry Applications, 2001, 37(2), 574-582.
  2. Loh, P. C. Holme, D. G. and Lipo, T. A. 2003. Synchronisation of Distributed PWM Cascaded Multilevel Inverter with Minimal Harmonic Distortion and Common Mode Voltage, IEEE Conf. Rec:0-7803-7754-0/03, 177-182.
  3. Mariethoz, S. and Rufer, A. 2004. Resolution and Efficiency Improvements for Three Phase Cascaded Multilevel Inverters, IEEE Conf. Rec: 0-7803-8399-0/04, 4441-4446.
  4. Xianglian Xu,Yunping Zou, Kai Ding, and Feiliu, 2004. Cascaded Multilevel Inverter with Phase-Shift SPWM and its Application in STATCOM, IEEE Conf. Rec: 0-7803-8730-9/04, 1139-1143.
  5. A. Keith, Corzine, W. Mike, Wielebski, Z. Fang, Peng, and Jin Wang, "Control of Cascaded Multilevel Inverter", IEEE Trans. on Power Electronics, 2004, 19(3), 732-738.
  6. Deng, Y. Wang, H. Zhang, C. Hu, L and He, X. 2005. Multilevel PWM Methods based on Control Degrees of Freedom Combination and Its Theoretical Analysis, IEEE Conf. Rec: 0-7803-9208-6/05, pp. 1692-1699.
  7. B. Shanthi, S. P. Natarajan, "Carrier Overlapping PWM Methods for Single Phase Cascaded Five Level Inverter", International Journal of Science and Technology of Automatic Control & Computer Engineering (IJ-STA, Tunisia). Special issue on Control of Electrical Machines, 2008, 590-601.
  8. Roozbeh Naderi, Abdolreza Rahmati, "Phase-Shifted Carrier PWM Technique for General Cascaded Inverters", IEEE Trans. on Power Electronics, 2008, 23(3), 1257-1269.
  9. Gierri waltrich and Ivo Barbi. "Three-Phase Cascaded Multilevel Inverter using Power Cell Switch with Two Inverter Legs in Series", IEEE Trans. on Industrial Electronics, 2010, 57(8), 2605-2612.
  10. Gierri Waltrich and Ivo Barbi. 2010. Three-Phase Cascaded Multilevel Inverter using Commutation Sub-Cells. IEEE Conf. Rec. 978-1-4244-3370-4/09. 362-368.
  11. Jose Ignacio Leon, Samir Kouro, Sergio Vazquez, Ramon Portillo, Leopoldo Garcia Franquelo, Juanmanuel Carrasco and Jose Rodriguez, "Multidimensional Modulation Technique for Cascaded Multilevel Converters", IEEE Trans. on Industrial Electronics, 2011, 58(2), pp 412-420.
  12. G. Yerri Babu, B. Loveswara Rao, "A Novel Cascaded Multilevel Inverter with Half Bridge and Full Bridge Cells in Series", International Journal of Science and Advanced Technology, 2012, 2(1), 71-76. .
  13. A. L. Batschauer, S. A. Mussa and M. L. Heldwein, "Three Phase Hybrid Multilevel Inverter Based on Half Bridge Modules", IEEE Trans. on Industrial Electronics , 2012, 59( 2), 668-678.
  14. N. Yousefpoor, S. H. Fathi, N. Farokhnia and H. A. Abyaneh, "THD Minimization Applied Directly on the Line-to-Line Voltage of Multilevel Inverters", IEEE Transactions on Industrial Electronics, 2012, 59(1), pp. 373-380.
  15. B. Urmila, and D. Subbarayudu, "Multilevel Inverters: A Comparative Study of Pulse Width Modulation Techniques", Journal of Scientific and Engineering Research, 2010, 1(13), 1-5.
Index Terms

Computer Science
Information Sciences

Keywords

Thd Cmli Stepped Thipwm 60 Degree Pwm Copwm