CFP last date
22 April 2024
Reseach Article

Real Time Estimation of Various Physiological Parameters by Analysis of PPG Signal

by Ashima Sahoo, G. S. Rath
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 57 - Number 15
Year of Publication: 2012
Authors: Ashima Sahoo, G. S. Rath
10.5120/9189-3611

Ashima Sahoo, G. S. Rath . Real Time Estimation of Various Physiological Parameters by Analysis of PPG Signal. International Journal of Computer Applications. 57, 15 ( November 2012), 11-15. DOI=10.5120/9189-3611

@article{ 10.5120/9189-3611,
author = { Ashima Sahoo, G. S. Rath },
title = { Real Time Estimation of Various Physiological Parameters by Analysis of PPG Signal },
journal = { International Journal of Computer Applications },
issue_date = { November 2012 },
volume = { 57 },
number = { 15 },
month = { November },
year = { 2012 },
issn = { 0975-8887 },
pages = { 11-15 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume57/number15/9189-3611/ },
doi = { 10.5120/9189-3611 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T21:00:31.094465+05:30
%A Ashima Sahoo
%A G. S. Rath
%T Real Time Estimation of Various Physiological Parameters by Analysis of PPG Signal
%J International Journal of Computer Applications
%@ 0975-8887
%V 57
%N 15
%P 11-15
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

In today's world, due to the living styles of the people there is a need to check the health issue continuously. People of different age groups need to self monitor their physiological body parameters regularly in order to control and prevent various abnormalities. This paper aimed at designing a noninvasive and real time physiological parameters estimation system using wavelets. This paper presents a novel algorithm and its real time implementation details for denoising highly non stationary PPG signals and finding out pulse rate, systolic & diastolic time and hence total cardiac cycle. Hence important parameters of cardiology can be easily measured at a time from PPG signals that can continuously monitor the health of an individual with a cardiac disorder.

References
  1. Yuan-ting Zhang, "Blood Pressure Devices", IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISS- MD), 2004.
  2. J. X. Sun, A. T. Reisner and R. G. Mark. A signal abnormality index for arterial blood pressure waveforms. Computers in Cardiology, 32:13 16, September 2005.
  3. Zhang Jun-feng,Wang Yan-yan,"Design for high data acquisition system based on PCL-816 and LabVIEW", Machinery Design &Manufacture,2007 Vol7, pp. 64-66
  4. Mohamad E. Alnaeb, Nasser Alobaid, Alexander M. Seifalia, Dimitri P. Mikhailidis and George Hamilton "Optical Techniques in the Assessment of Peripheral Arterial Disease" Current Vascular Pharmacology, 2007
  5. R. S. Khandpur, Handbook of Biomedical Instrumentation, 2nd ed. New Delhi: Tata McGraw-Hill Publishing Company Limited, 2003, pp. 113.
  6. Leslie Cromwell , Fred J. Weibell, Erich A. Pfeiffer, ' Biomedical Instrumentation and Measurements', Second Edition, Prentice hall of India, New Delhi, 1997
  7. Singh Kalsi, Mastan, "Design of Arterial Blood Pressure, Heart Rate Variability and Breathing Rate Monitoring Device"(2009). EE 4BI6 Electrical Engineering Biomedical Capstones
  8. John Allen, "Photoplethysmography and its application in clinical physiological measurement" Physiol. Meas. 28,R1–R39 2007
  9. D . J. Pitson, A. Sandell , R. v a den Hout , J. R. Stradling, 'Use of Pulse transit time as a measure of inspiratory effort in patients With obstructive sleep apnoea', ERS Journals Limited, 1995
  10. P. S. Addison, "Wavelet Transforms and the ECG": a review, Physiological Measurement 26 (2005) R155–R199
  11. Mohammad Ali Tinati and Behzad Mozaffary, "A Wavelet Packets Approach to Electrocardiograph Baseline Drift Cancellation", Communication Department, Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz1666- 16471,Iran
  12. Dai Junwei, Wang Boliang, "A New Design of PPG Pulse Sensor and Noise Analysis", Modern Electronics Technique, 2006, Vol. 2, pp. 78-80.
Index Terms

Computer Science
Information Sciences

Keywords

PPG DWT Pulse Rate Total Cardiac Cycle LabVIEW Realtime