CFP last date
20 May 2024
Reseach Article

MATLAB based TF Estimation and Verification of Moisture-Free PVC Temperature

Published on February 2013 by S. S. Nirmale, A. C. Shaikh, H. V. Kulkarni, R. R. Mudholkar
International Conference on Recent Trends in Information Technology and Computer Science 2012
Foundation of Computer Science USA
ICRTITCS2012 - Number 10
February 2013
Authors: S. S. Nirmale, A. C. Shaikh, H. V. Kulkarni, R. R. Mudholkar
68dc0f19-378b-4fe5-816d-10dac26cc646

S. S. Nirmale, A. C. Shaikh, H. V. Kulkarni, R. R. Mudholkar . MATLAB based TF Estimation and Verification of Moisture-Free PVC Temperature. International Conference on Recent Trends in Information Technology and Computer Science 2012. ICRTITCS2012, 10 (February 2013), 12-16.

@article{
author = { S. S. Nirmale, A. C. Shaikh, H. V. Kulkarni, R. R. Mudholkar },
title = { MATLAB based TF Estimation and Verification of Moisture-Free PVC Temperature },
journal = { International Conference on Recent Trends in Information Technology and Computer Science 2012 },
issue_date = { February 2013 },
volume = { ICRTITCS2012 },
number = { 10 },
month = { February },
year = { 2013 },
issn = 0975-8887,
pages = { 12-16 },
numpages = 5,
url = { /proceedings/icrtitcs2012/number10/10316-1457/ },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Proceeding Article
%1 International Conference on Recent Trends in Information Technology and Computer Science 2012
%A S. S. Nirmale
%A A. C. Shaikh
%A H. V. Kulkarni
%A R. R. Mudholkar
%T MATLAB based TF Estimation and Verification of Moisture-Free PVC Temperature
%J International Conference on Recent Trends in Information Technology and Computer Science 2012
%@ 0975-8887
%V ICRTITCS2012
%N 10
%P 12-16
%D 2013
%I International Journal of Computer Applications
Abstract

Insulated wire manufacturing process goes through number of phases before yielding a desired quality of insulated wire. The first phase of wire manufacturing is the controlling of PVC- temperature to make it free from the moisture. In this paper, we describe the estimation of first order Transfer Function (TF) with dead time for the PVC placed in the tray of Electric Oven (EO). The TF is estimated using the real time measured response of PVC temperature in EO for the applied step change in power to EO and with the help of MATLAB. The estimated TF was verified by making simulation model for it in MATLAB and comparing the simulated result with measured data. The time domain response of estimated TF shows closely represents the real time behavior of PVC temperature in EO.

References
  1. Leonard I. Nass and Charles A. Heiberger. "Encyclopedia of PVC," Vol. 1: Resin. Manufacture and Properties' 2nd Edition, Marcel Dekker Inc. (1982).
  2. PRECISE CABELS, Shirgaon MIDC, Gokul Shirgaon, Kolhapur.
  3. Emine Dogru Bolat, 2007, "Implementation of Matlab-SIMULINK Based Real Time Temperature Control for Set Point Changes", International Journal Of Circuits, Systems and Signal Processing, Vol. 1, No. 1, pp. 54-61.
  4. Rohit Ramachandran, S. Lakshminarayanan and G. P Rangaiah, 2005, "Process Identification Using Open-Loop and Closed-Loop Step Responses", Journal of The Institution of Engineers, Singapore, Vol. 45, No. 6.
  5. Saïda Bedoui, Majda Ltaief, Kamel Abderrahim, 2012, "New Method for the Systematic Determination of the Model's Base of Time Varying Delay System", International Journal of Computer Applications, Vol. 46, No. 1, pp. 13-19.
  6. Warren Scott Ferguson, 2001, "Optimal CLOSED-LOOP Experiments FOR Accurate STEP RESPONSE Model Identification", a Thesis of University of Toronto.
  7. Tony Kealy, Aidan O'Dwyer, June 2002, "Closed Loop Identification Of A First Order Plus Dead Time Process Model Under PI Control", Proceedings of the Irish Signals and Systems Conference, University College, Cork, pp. 9-14.
  8. Un-Chul Moon and Kwang. Y. Lee, 2009, "Step-Response Model Development for Dynamic Matrix Control of a Drum-Type Boiler–Turbine System", IEEE Transactions on Energy Conversion, Vol. 24, No. 2, 423-430.
  9. Parasana Sankara Rao, Kiran Kumar Reddi, 2012, "Performance Evaluation of Regression Techniques for Effort Estimation", International Journal of Computer Applications, Vol. 52, No. 6.
  10. O'Dwyer, Aidan, 2000, "Time delayed process model parameter estimation: a classification of techniques", Proceedings of UKACC International Conference on Control 2000, Cambridge, England, September 4-7.
  11. "Proces Control Laboratory Experimental Procedure and Instructions for Preparing Lab-Report", document available at http://www. che. iitb. ac. in/courses/uglab/ cl431/controlcompre. pdf dated 03/12/2011.
  12. Mazidi M. A. , Mazidi J. G. , McKinlay R. D. , "The 8051 Microcontroller and Embedded Systems" Pearson Education India, 2007.
  13. Sunil S. Nirmale, Tukaram R. Kumbhar, R. R. Mudholkar, 2011, "Fuzzy based Decision System for Moisture-Free PVC Temperature", International Journal of Applied Engineering Research, Vol. 6, No. 12, pp. 1543-1554.
  14. Larry D. Schroeder, David L. Sjoquist, Paula E. Stephan, Understanding Regression Analysis: An Introductory Guide, SAGE Publication, 1986.
  15. 'fmincon' help available at http://www. mathworks. in/ help/optim/ug/fmincon. html dated 05/12/2011.
  16. Mathworks Inc. MATLAB User Manual for MATLAB and Simulink Toolbox.
Index Terms

Computer Science
Information Sciences

Keywords

Pvc Moisture-free Temperature Insulated Wire Electric Oven Tf Estimation Matlab Simulation